Brand |
---|

Brand |
---|
The DC PowerCube 48 VDC – 80 A can deliver up to 4.3 kW, enough to charge batteries and battery banks quickly whilst still providing the various DC and AC loads with power for all equipment on marine and mobile/off-grid applications. The DC PowerCube 48 VDC – 80 A can even be used as a power supply, without batteries, as the smooth output voltage is incredibly uniform and ripple free.
The DC PowerCube 48 VDC – 80 A battery charger/power supply is designed for extensive electrical systems with a large battery bank and significant DC consumption. The DC PowerCube 48 VDC – 80 A converts the delivered power (from the grid or generator) to DC for lighting, electronic equipment, pumps and other DC loads.
ARTICLE NUMBER | |
---|---|
60202003 | DC PowerCube 48 V – 80 A |
DIMENSIONS & WEIGHT | |
---|---|
Weight kg (lb.) | 26 (57.3) |
Length x width x height, mm (in.) | 268 x 316 x 575 (10.6 x 12.4 x 22.6) |
GENERAL SYSTEM SPECIFICATIONS | |
---|---|
Nominal battery voltage | 48 VDC |
Output current | 0 – 100 A (short circuit protected) |
Output voltage | 43.0 / 57.0 VDC |
Recommended battery capacity: | 200 to 1000 Ah |
charge characteristic | 3+ step charge characteristic |
Slave charger | 12 V – 20 A (3+ step charge characteristic) short circuit protected |
INPUT SPECIFICATIONS | |
---|---|
Grid input voltage range | 90 – 264 VAC (45 – 65 Hz), (3 wire connection) |
Grid input current | Adjustable, from 2 A to 16 A |
PM generator input range | 80 – 300 VAC (30 – 500 Hz), (3 wire connection) |
PM input current | Adjustable, from 2 A to 14.5 A |
Power factor (cos phi) | > 0.85 |
Power Factor Correction (PFC) | EN 61000-3-2 |
Temperature compensation | -60 mV / °C |
TECHNICAL SPECIFICATIONS | |
---|---|
Supported battery types | Open and sealed lead acid: Gel / Traction / AGM / Spiral and Lithium-ion |
Battery leakage current | <5 mA per battery |
Charge voltages | Bulk, Absorption, Float |
Charge voltage AGM / GEL at 25°C | 57.60 VDC, 57.00 VDC, 54.40 VDC |
Charge voltage Traction at 25°C | 58.40 VDC, 57.80 VDC, 53.00 VDC |
Charge voltage Open lead acid at 25°C | 57.00 VDC, 57.00 VDC, 53.00 VDC |
Charge voltage Lithium ION at 25°C | 57.60 VDC, 54.40 VDC, 53.00 VDC |
Return current from absorption to float | 6% of Imax |
PowerCube status on/off | Digital output (relay, two-way contact) |
Failure | Digital output (relay, two-way contact) |
AC grid disabled | Digital input (potential free input, closed is disabled) |
PM input disabled | Digital input (potential free input, closed is disabled) |
Conformity | Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022,EN 61000-3-2, 62040-2 Low voltage directive 2006/95/EC: EN 62040-1-1, EN 50091-2, EN 60950-1 |
PROTECTIONS | |
---|---|
PM input isolation protection | Yes (open collector output 30 VDC, 100 mA) |
Over temperature protection | Yes, derating above 40°C, shutdown at high temperatures. (with automatic restart after cooling down) |
Overvoltage protection (manual restart needed) | 68 VDC +/- 0.5 VDC |
Ingress Protection index | IP21 |
MECHANICAL SPECIFICATIONS | |
---|---|
Main battery connection | 2 x M10 studs |
Slave battery connection | 1 x M5 stud |
Earth grounding lug | 1 x M6 stud |
AC grid input | 3 x M3 screw terminal block |
PM grid input | 3 x M3 screw terminal block |
Remote control panel | RJ12 |
Battery temperature sensor | RJ12 |
Whisper Connect CANbus | RJ45 |
Voltage sense | Phoenix MSTB 2.5 / 2-ST-5.08 |
Digital outputs | 6 x fastons (6.3 x 0.8) |
Digital inputs | 4 x fastons (6.3 x 0.8) |
Operating temperature range | -20 – 55°C (derating above 40°C) |
Relative humidity in operation | up to 95% without condensation |
Ventilation | Combined cooling (convection and forced (variable speed)) |
Acoustic level | <52 dB |
Warranty | 2 years |
Accessories | Battery temperature sensor and remote control panel |