• WHO WE ARE
  • SHOP
  • WHAT WE DO
  • MEDIA
  • CONTACT
0 items د.إ0.00
Menu
FPGT General Trading LLC
0 items د.إ0.00
Click to enlarge
Home All Products 1-10kVA RMI Series Inverter for Utility and Telecom
Gellyte Range VRLA Battery
Gellyte Range VRLA Battery
Back to products
1-80kVA RMI-M Series Inverter for Utility and Telecom (parallel type)
1-80kVA RMI-M Series Inverter for Utility and Telecom (parallel type)
EverExceed

1-10kVA RMI Series Inverter for Utility and Telecom

SKU: 1-10kVA RMI Series Inverter for Utility and Telecom Category: All Products Tags: 1-10kVA, Inverter, RMI, Series, Telecom, Utility
Share:
  • Additional information
  • Description
Additional information
Brand

EverExceed

Customer Application

Airports

Customer Type

Airports

Description

EverExceed RMI series is a new Off-grid inverter with advanced technology and improved modularity with high efficiency (≥90%). The series has a vast range of 1-10kVA. This inverter has been designed to offer low cost per VA and offers our standard features, high level of intelligence, reliability and smart characteristics.

  • Brand:EverExceed
  • DC Input Voltage:24VDC/48VDC/110VDC/125VDC/220VDC
  • AC Output Voltage:110VAC/220VAC
  • Rated Power:1/2/3/4/5/6/8/10KVA Optional
  • Rated Output Frequency:50Hz/60Hz

Technical Features:

 

High flexibility Advanced technology Smart monitoring
Supports TCP/IP protocol to utilize Ether CAT and monitoring software, three emergency passive dry contacts for DC input failure, AC input failure or AC output failure; Adopts noise reduction technology to avoid interference with other communication equipments; User friendly LCD display to check the operation mode /working status; Supports communication function and real-time monitoring function;
Modular design High protection High reliability
19″ rack mounted inverter for integrated system, adopts microcomputer CPU for intelligent control; Multiple protections ensure safe operation without any attendance; Built-in bypass switch to ensure continuous and stable power supply;

 

 

Working Diagram:

Factory

 

Technical Data(220VAC output)

Technical Data (220VAC OUTPUT):
MODEL(HV) RMI1000 RMI2000 RMI3000 RMI4000 RMI5000 RMI6000 RMI8000 RMI10000
24V Allowable range of input DC voltage Cutoff voltage: ≤ 20Vdc, or ≥30Vdc   Startup voltage: 22Vdc-28Vdc
48V Allowable range of input DC voltage Cutoff voltage: ≤ 40Vdc, or ≥60Vdc   Startup voltage: 45.5Vdc-57Vdc
110V Allowable range of input DC voltage Cutoff voltage: ≤ 90Vdc, or ≥135Vdc   Startup voltage: 104Vdc-131Vdc
220V Allowable range of input DC voltage Cutoff voltage: ≤ 180Vdc, or ≥275Vdc   Startup voltage: 208Vdc-260Vdc
24V DC Input Maximum 42A 83A 125A – – – – –
48V DC Input current 21A 42A 63A 83A 104A 125A 167A 208A
110V DC Input 9A 18A 27A 36A 45A 55A 72.7A 90.9A
220V DC Input 4.5A 9A 13.5A 18A 22.5A 27A 36A 45.5A
AC by-pass Allowable by-pass voltage 170~270VAC
input (Vac)
Rate input current(A) 4.5A 9.1A 13.6A 18.2A 22.7A 27.2A 36.3A 45.4A
By-pass conversion time ≤5ms
(ms)
AC output Rated capacity(VA) 1KVA 2KVA 3KVA 4KVA 5KVA 6KVA 8KVA 10KVA
Rated output power(W) 800W 1600W 2400W 3200W 4000W 4800W 5600W 7000W
Output voltage 220Vac ( ± 10%V Adjustable LCD Display )
Output  frequency 50-60Hz ( Auto sync with bypass input )
Rated output current 3.6A 7.3A 11.0A 14.5A 18.2A 21.8A 25.4A 31.8A
Output voltage precision(V) 220Vac ± 1.5%
Output frequency precision(Hz) 50Hz ± 0.1% or 60Hz ± 0.1%
Waveform Pure sine wave
Total harmonic distortion(THD) ≤3% ( linear load )
Dynamic response time Dynamic response time: <5% Vnom for load change 0% to 100%,transient time <5 ms
Power factor( PF ) >0.8 >0.7
Overload capacity 101%~120% load/continue 60s; 121%~150% load/continue 10s
Inversion efficiency ≥85% (80% liner load)
By-pass conversion time(ms) ≤ 5ms
Working environment Dielectric strength 1500Vac/10mA/60s
Noise ( 1m ) < 55dB < 60dB < 55dB
Operating environment -20°C~+50°C
temperature
Humidity 0~90%, no moisture condensation
Operating altitude ( m ) ≤ 2000m
Indication LCD display Input and output voltage, frequency, output current, temperature, percentage, etc.
Inverter status Normal mains, normal inversion, battery under-voltage and output overload.

 

 

Technical Data(110VAC output)

 

Technical Data (110VAC OUTPUT):
MODEL(LV) RMI1000 RMI2000 RMI3000 RMI4000 RMI5000 RMI6000
24V Allowable range of input DC voltage Cutoff voltage: ≤ 20Vdc, or ≥30Vdc   Startup voltage: 22Vdc-28Vdc
48V Allowable range of input DC voltage Cutoff voltage: ≤ 40Vdc, or ≥60Vdc   Startup voltage: 45.5Vdc-57Vdc
110V Allowable range of input DC voltage Cutoff voltage: ≤ 90Vdc, or ≥135Vdc   Startup voltage: 104Vdc-131Vdc
220V Allowable range of input DC voltage Cutoff voltage: ≤ 180Vdc, or ≥275Vdc   Startup voltage: 208Vdc-260Vdc
24V DC Input Maximum current 42A 83A 125A – – –
48V DC Input 21A 42A 63A 83A 104A 125A
110V DC Input 9A 18A 27A 36A 45A 55A
220V DC Input 4.5A 9A 13.5A 18A 22.5A 27A
AC by-pass input Allowable by-pass voltage (Vac) 85~135VAC
Rate input current(A) 9A 18A 27A 36.5A 45.5A 54.5A
By-pass conversion time (ms) ≤5ms
AC output Rated capacity(VA) 1KVA 2KVA 3KVA 4KVA 5KVA 6KVA
Rated output power(W) 800W 1600W 2400W 3200W 4000W 4800W
Output voltage 110Vac ( ± 5V Adjustable LCD Display )
Output  frequency 50-60Hz ( Auto sync with bypass input )
Rated output current 7.2A 14.4A 21.8A 29A 36.3A 43.6A
Output voltage precision(V) 110Vac ± 1.5%
Output frequency precision(Hz) 50Hz ± 0.1% or 60Hz ± 0.1%
Waveform Pure sine wave
Total harmonic distortion(THD) ≤3% ( linear load )
Dynamic response time Dynamic response time: <5% Vnom for load change 0% to 100%,transient time <5 ms
Power factor( PF ) >0.8 >0.7
Overload capacity 101%~120% load/continue 60s; 121%~150% load/continue 10s
Inversion efficiency ≥85% (80% liner load)
By-pass conversion time(ms) ≤ 5ms
Working environment Dielectric strength 1500Vac/10mA/60s
Noise ( 1m ) < 55dB < 60dB
Operating environment -20°C~+50°C
temperature
Humidity 0~90%, no moisture condensation
Operating altitude ( m ) ≤ 2000m
Indication LCD display Input and output voltage, frequency, output current, temperature, percentage, etc.
Inverter status Normal mains, normal inversion, battery under-voltage and output overload.

Fortress Protection Group Technologies –
Where Your Security is Our Priority.

  • USEFUL LINKS
    • About Us
    • Contact Us
    • Shop
    • Media
  • LEGAL
    • Privacy Policy
    • Terms & Conditions
  • Contact Us
    • Phone: 00971(0)569436363
    • Email: contact@fp-me.com
    • Address: Abu Dhabi | UAE
    • Website: www.fp-me.com
    • c/o: FPGT General Trading LLC
© 2024 Fortress Protection Group Technologies | DEVELOPED BY Babapinnak Media LLP.
Close
  • WHO WE ARE
  • SHOP
  • WHAT WE DO
    • SECURITY SYSTEMS
    • DETECTION & IDENTIFICATION SYSTEMS
    • INSPECTION SYSTEMS
    • ROBOTICS
    • ANALYTICAL SYSTEMS
    • WAREHOUSING
    • BATTERIES & POWER
    • APPLICATIONS
    • SERVICE AND SUPPORT
  • MEDIA
  • CONTACT
Shopping cart
Close
Shop
0 items Cart