10-40kVA PowerChampion RM Series Rack Online UPS
380/400/415VAC, 3:3
The PowerChampion RM Series Rack is double conversion online UPS with fully DSP controlled technology. With its flexible configuration of 3/3 and 3/1, compact design, it is the ideal choice for modern data center.
Technical features
![]() |
![]() |
![]() |
Rack design |
Smart display |
Energy efficient |
Rack design, compatible with 19* standard rack cabinet, convenient to be integrated with servers | 5.5″ touch color LCD with graphic display, more information displayed and easier for customer to operate | High efficiency operation in double conversion mode up to 98%. |
![]() |
![]() |
![]() |
Intelligent charging management |
Flexible configuration |
Friendly interface |
The system itelligenty control the whole process of the charging and discharging, effectively improving the life time of the battery. | The system can be configured to 3/3 and 3/1 | RS232,RS485, SNMP, Dry contacts, USB;Optional communication interface: Parallel kits |
Application
IDC (Internet data Center), Network servers and workstations, Control system, Communication system, Office
MODEL | PWR10L | PWR15L | PWR20L | PWR25L | PWR30L | PWR40L |
Power Rating | 10KVA/10KW | 15KVA/15KW | 20KVA/20KW | 25KVA/25KW | 30KVA/30KW | 40KVA/40KW |
Main | ||||||
Input | 3 P + N+ PE | |||||
Rate Voltage | 380/400/415VAC (line-ine) | |||||
Rate Frequency | 50/60Hz | |||||
Input Voltage Range | 304~478Vac (line-ine),full load | |||||
228V~304Vac (line-ine), full load; 228V~304Vac (line-ine),derate from 75% to 100% load | ||||||
Input Frequency Range | 40Hz~70Hz | |||||
Input PF | >0.99 | |||||
Input THDi | <4% (100% Linear Load) | <3% (100% Linear Load) | ||||
Bypass | ||||||
Rate Voltage | 380/400/415Vac (line-ine) | |||||
Rate Frequency | 50/60Hz | |||||
Input Voltage Range | Selectable, -40%~+25% | |||||
Bypass Frequency Range | Selectable, ±1Hz, ±3Hz, ±5Hz | |||||
Bypass Overload | 125%, Long time; 130%, 10mins; 150%,1min; >150%,1s | |||||
Output | ||||||
Rate Voltage | 380/400/415Vac (line-ine) | |||||
Rate Frequency | 50/60Hz | |||||
Output PF | 1 | |||||
Output THDu |
<1% from 0% to 100% linear load
<5.5% full non-linear load according to IEC/EN62040-3
|
<1% from 0% to 100% linear load
<5% full non-linear load according to IEC/EN62040-3
|
||||
Inverter Overload | 110% for 1 hour; 125% for 10 min; 150% for 1min; >150% for 200ms | |||||
Battery | ||||||
Battery Number | ±240VDC | |||||
Charger Accuracy | 1% | |||||
Charger Capacity | up to 20% *Output power | |||||
Battery Cold Start | Yes | |||||
Efficiency | ||||||
AC Mode | 95.0%max | 95.5%max | 96.0%max | 96.0%max | ||
Battery Mode | 94.5%max | 95%max | 95.5%max | 95.5%max | ||
System | ||||||
Display | LED + LCD+Touch Screen | |||||
Interface | RS232(only 10-25K), USB(only 40K), RS485, Programmable dry contact | |||||
Option | SNMP, parallel kit | SNMP, parallel kit, LBS | ||||
Environmental | ||||||
Operation Temperature | 0 ~ 40 ℃ | |||||
Storage Temperature | -40 ~ 70 ℃ | |||||
Relative Humidity | 0 ~ 95% Non condencing | |||||
Noise (1 meter) | 65dB @ 100% load, 62dB @ 45% load | |||||
Phisical data | ||||||
Dimension W*D*H (mm) | 438*780*130 | 438*780*130 | 438*700*174 | 438*700*174 | ||
Weigh (kg) | 25 | 30 | 41 | 41 |