The DC Modular Battery Protect Relay has the same capabilities as the Remote Battery Switch. It is a smart high current magnetic latching contactor, that can handle continuous DC currents of up to 350 Amps.
Whereas the Remote Battery Switch is mainly used as a locally or externally controlled battery load switch, the Modular Battery Protect Relay has a number of additional features. Most importantly, it can protect your battery without the need for an external measurement and control device.
ARTICLE NUMBER | |
---|---|
50214740 | Modular Battery Protect Relay 48 V / 350 A |
TECHNICAL SPECIFICATIONS | |
---|---|
Rated voltage | 60 VDC |
Nominal current | 500 A |
Cranking current (1 min.) | 1000 A |
Nominal make / break current | 500 A (0 – 34 VDC) / 350 A (35 – 60 VDC) |
Peak make / break current | 1600 A (0 – 34 VDC) / 1200 A (35 – 60 VDC) |
CONTROL CIRCUIT (ELECTRICAL) | |
---|---|
Coil / supply voltage (+ VDC) | 34 – 68 VDC |
Coil / supply current (idle state)* | < 100 qA |
Coil / supply current (state change)* | < 1.5 A |
* | Due to the magnetic latch construction, the WP-MBP draws virtually no current in the ON or OFF state. A current draw only exists shortly (500 ms max.) when changing the state of the contact. |
GENERAL | |
---|---|
Dimensions (W x D x H) mm | 50 x 94 x 150 |
Weight | 800 g |
Remote control | By control wires |
Local control ** | ON/Standby, Open and Close contact, Override mode |
Indicators | Contact open/close, Undervoltage disconnect, Override mode, Error and Setup |
Mechanical life | 100000 cycles |
Electrical life | 10000 cycles |
Operating temperature range | -20 up to 60°C |
Connection stud size | M10 |
DC Modular grid size | 1 x 3 |
Protection class | IP65 |
Standards | CE certified (EMC Directives UNECE Regulation 10 and 2014/30/EU, Low voltage Directive 2014/35/EU, RoHS Directive 2011/65/EU and Ignition protection standard ISO 8846) |
** | Using the top side buttons, one can manually override the switch state as commanded through the control wires. A dedicated ‘ON / Standby’ button also allows the user to put the WP-MBP in a standby mode with open contact. In this mode any command from the control wires and/or manual override buttons are ignored. |