• WHO WE ARE
  • SHOP
  • WHAT WE DO
  • MEDIA
  • CONTACT
0 items د.إ0.00
Menu
FPGT General Trading LLC
0 items د.إ0.00
Click to enlarge
Home BATTERIES & POWER SAFT MSX SAFT Battery MSX 80
SUN+ 1830 SUN+ 1520 SUN+ 1620 SUN+ 1775 SUN+ 1320 SUN+ 1370 SUN+ 1245 SUN+ 1215 SUN+ 1170 SUN+1470 SUN+1420 SUN+ 1270 SUN+ 810 SUN+ 790 SUN+ 760 SUN+ 930 SUN+ 860 SUN+ 835 SUN+ 1115 SUN+ 1065 SUN+ 1015 SUN+ 960 SUN+ 610 SUN+ 660 SUN+ 415 SUN+ 645 SUN+ 370 SUN+ 355 SUN+ 555 SUN+ 505 SUN+ 485 SUN+ 455 SUN+ 710 UN+ 50 SUN+ 136 SUN+ 100 SUN+ 235 SUN+ 200 SUN+ 175 SUN+ 150 SUN+ 320 SUN+ 305 SUN+ 275 SUN+ 250 SUN+ 405
SAFT batteries SUN+ 1830
Back to products
SAFT Battery MSX 100
SAFT Battery MSX 100
SAFT

SAFT Battery MSX 80

SKU: MSX 80 Categories: All Products, BATTERIES & POWER, MSX, SAFT Tags: MSX, MSX 80, NICD Batteries, SAFT Brand: SAFT
Share:
  • Additional information
  • Description
Additional information
Brand

SAFT

Customer Application

Railway

,

Transportation

Customer Type

Airports

,

Etihad Rail

,

Government Entities

,

Oil & Gas

,

Transportation Authority

Description

MSX 80 – Saft Batteries

Providing high power capability and cycling performance

High-power capability and high-cycling performance for railway backup and engine starting

Saft’s on-board solutions provide reliable power, reduced weight and volume of on-board components, low maintenance and improved battery efficiency to help train manufacturers and operators work more efficiently.

Saft’s MSX wide capacity range with its high power and energy capabilities provide both energy for backup applications and high power for starting diesel engines on locomotives and DMUs. These nickel-based batteries are ideal for modern electric trains such as tram-trains, trams, EMUs and high-speed trains, including the safety-critical demands of electromagnetic braking applications.

Features & Benefits

  • Low-maintenance and long service life
  • Optimal size of onboard battery system frees up space and offers 30% savings in weight and 40% saving in volume compared to conventional batteries
  • A single MSX battery can perform both backup and engine starting functions so that two onboard systems can be replace by just one MSX system

Technical Specifications

  • Proven Ni-Cd Sintered/PBE technology that last more than 15 years
  • High power capability and high cycling performance
  • Operate in a wide temperature range of -30°C to +50°C
  • Wide range of capacities from 70 Ah to 260 Ah
  • For a battery stored for more than 3 months or at T > +30°C, or more than 6 months at T > +20°C:
  • Discharge the battery at 0.2 C5 A down to an average 1V per cell.
  • Maintain the battery in open circuit for 8 hours or until the battery temperature is between +10°C and +30°C.
  • Charge the battery at 0.2 C5 A for 8 hours. 5.2. The batteries are delivered discharged

Caution: even if the battery is discharged, there remains a residual charge that may cause an electric shock. Charging and discharging should be done at constant current.

  • For a battery placed into service immediately after delivery or after less than one year of storage:
  • Preferred solution: constant current charge; charge the battery at 0.2 C5 A for 8 hours. Caution: during constant current charging the battery box must be open.
  • Other solution: Constant voltage charge: 1.55V/cell for 20 hours with the current limited at 0.2 C5 A.

For a battery stored more than 1 year:

  • Charge the battery at 0.2 C5 A for 8 hours.
  • Discharge the battery at 0.2 C5 A down to an average 1V per cell.
  • Maintain the battery in open circuit for 8 hours or until the battery temperature is between +10°C and +30°C.
  • Charge the battery at 0.2 C5 A for 8 hours.
  • The battery is ready for use.

Charging in service

  • 1.47 V/cell at +20°C (+68°F) with voltage compensation: -3 mV/°C/cell (-1.7 mV/°F/cell). For higher charging voltages consult with FPGT General Trading
  • Boost charge according to IEC62973-2.

Topping-up

  • Before topping-up operation, the water filling circuit of the battery must be checked for tightness (no leaks) using a pressure test (a kit may be supplied by SAFT). Use only distilled and deionized water for topping-up. Connect distilled water tank to the selfclosing inlet. Topping-up is completed when an excess of 1 litre of water is measured at the outlet of the water filling circuit. Topping-up can be performed by Saft’s gravity kit or by using Saft’s water filling stations. If charge at constant current: operation must be carried on charged cells with a rest time of minimum of 2 hours. If charge at constant voltage on the train, the topping-up can be carried out at any time. Topping-up can be performed every 6 years (if the annual average cell temperature is below +30°C and the battery is used as a back-up battery) by gravity or using adapted pump with a flow rate of 0.7 l/min at a relative pressure of 0.3 bar maximum.

Research: Extending the role of backup batteries | In depth | Railway Gazette InternationalResearch: Extending the role of backup batteries | In depth | Railway Gazette International

Fortress Protection Group Technologies –
Where Your Security is Our Priority.

  • USEFUL LINKS
    • About Us
    • Contact Us
    • Shop
    • Media
  • LEGAL
    • Privacy Policy
    • Terms & Conditions
  • Contact Us
    • Phone: 00971(0)569436363
    • Email: [email protected]
    • Address: Abu Dhabi | UAE
    • Website: www.fp-me.com
    • c/o: FPGT General Trading LLC
© 2024 Fortress Protection Group Technologies | DEVELOPED BY Babapinnak Media LLP.
Close
  • WHO WE ARE
  • SHOP
  • WHAT WE DO
    • SECURITY SYSTEMS
    • DETECTION & IDENTIFICATION SYSTEMS
    • INSPECTION SYSTEMS
    • ROBOTICS
    • ANALYTICAL SYSTEMS
    • WAREHOUSING
    • BATTERIES & POWER
    • APPLICATIONS
    • SERVICE AND SUPPORT
  • MEDIA
  • CONTACT
Shopping cart
Close
Shop
0 items Cart