Brand | |
---|---|
Customer Application |
Airports |
Customer Type |
Airports |
Brand | |
---|---|
Customer Application |
Airports |
Customer Type |
Airports |
Technical features
![]() The chargers feature two independent systems in one cabinet, with outputs of 220V 60A and 24V 60A. |
![]() Dual isolation transformers for voltage conversion and isolation. |
![]() One system charges 105 batteries, the other 12, with power selectable from either charger or total voltage to meet varying voltage needs. |
![]() The master unit runs under normal conditions, and the slave unit takes over in case of a fault. Once the fault is resolved, both units can operate together or independently. |
![]() Supports Modbus TCP/IP communication and dry contact function, making it easy to connect with the customer’s system. |
![]() Customers can monitor charging status and real-time alarms via a touch screen. |
GENERAL | |
Model | uXcel ultra -220V80A/16V60A |
Topology | 6 pulse full bridge thyristor rectifier |
Control | Microprocessor controlled system |
Standars | IEC60146、IEC60439、IEC60725、IEC61000-6-2、IEC61000-6-4、IEC62040(-1,-2,-3) |
Configuration | Parallel(One work, one standby) |
ENVIRONMENT | |
Operation temperature | 0 – 50℃ |
Storage temperature | -20 to +70℃ |
Relative humidity | < 95% ( no condensation of moisture ) |
Altitude | 1000 m Max without derating |
INPUT PARAMETERS | |
Input isolation transformer | Galvanically isolated / Primary & Secondary earth screened |
AC voltage and tolerance | 380VAC±10%, three-phase |
Input frequency and tolerance | 50Hz/60Hz ±5% |
Input protection | Input MCCB Thermic magnetic overcurrent protection,AC SPD |
OUTPUT PARAMETERS | |
Nominal output voltage | 220VDC/16VDC |
Float voltage | 0-300V/0-24V adjustable |
Boost voltage | 0-300V/0-24V adjustable |
Voltage stability | ±1% in float mode, input within tolernce |
Nominal output current | 80/60A |
Output current adjustment | 0‐100% of Nominal Output Current |
Output ripple | 1% RMS (with battery connected) |
Mode of operation | constant voltage/constant current |
Static voltage regulation | < 1% |
Efficency | 88% |
Filter | L-C Filter |
Output breaker | DC1 battery MCCB,DC1 load MCCB,DC2 battery MCCB,Total load MCCB |
Battery bank | Lead Acid or Nickel Cadmium vented or recombination |
Boost voltage (V/C) | 2,35 lead acid battery 1,60 NiCd Battery (Depends on battery manufacturer recommendation) |
Float voltage (V/C) | 2,25 lead acid battery 1,40 NiCd battery (Depends on battery manufacturer recommendation) |
MECHANICAL PARAMETERS | |
External protection | IP20, Cold rolled sheet |
Panel thickness | Load Bearing: 2 mm, Non Load Bearing: 1.5 mm |
Frame Colour | RAL7035 |
Noise(dB ) | <50 dB |
Cooling | Fan cooling |
Cable Entry | Bottom |
Dimensions | 1600H*1200W*800D(mm) |
DISPLAY PANEL & MEASUREMENT | |
Meter | DC1 voltage, DC2 voltage,Total voltage,DC1 current,DC1 current |
Protection | Charger fault protection (DC overvoltage, DC overcurrent, Over temperature) |
Alarm | Charger1 fault protection,Charger2 fault protection,BAT over temperature, Mains fault,DC1 overvoltage,DC1 undervoltage,DC2 overvoltage,DC2 undervoltage |
Indication | LED lamp |
Display | LCD display |
OTHER FUNCTIONS | |
Other funtions | |
Battery temperature compensation | 3mV/cell, adjustable |
Language | Customized |
COMMUNICATION | |
Communication | RS485, Modbus RTU |
Dry contact | Charger fault |