The EverExceed uXcel® range industrial battery charger is the flagship charger of EverExceed Industrial Power solutions. It integrates proven design topology with the latest advanced digital control technology to control the thyristor bridge rectifier and provides the most reliable and trouble-free performance in any electrical and industrial environments.
- Lead Time:Normally 4~6 weeks
- Brand:EverExceed
- Nominal DC Voltage(Output):24/48/110/125/220/240/400V
- Nominal DC Current(Output):10-1500A
- Input AC Voltage:Single phase 1×230V(220,240)/Three phase 3×400V(380,415)other input voltage can be customized
- Battery Type:Lead acid batteries, nickle cadmium batteries, lithium batteries
- Communication:RS232/RS485 Modbus, TCP/IP,DNP3.0(optional)
- OEM/ODM Service:Yes, customized
Technical features
|
|
|
Large LCD display |
Leading Technology |
High Reliability and High MTBF |
User friendly operation with large LCD display, optional touch screen with the choices of 8 languages ensure easy maintenance and operation. Smart communication and Remote Monitoring.
|
The embedded micro-computer controller processes signals 10 times faster than standard analog methods. |
Fully automatic battery management with “four remote”
functions meeting requirements of untended duty control.
|
|
|
|
Isolation transformer |
Flexible maintenance and Reduced MTTR |
Long design life up to 20+years |
Filter more than 3 harmonics in the power grid interference to the system equipment, while strengthening the operation security of the system.
|
The design make it easy for front-access to all vital modules modules of the charger
Versatile constant voltage and constant current charging modes
Smart communication and Remote Monitoring through isolated RS232, RS485, Ethernet. Full data logging. |
System design life up to 20+ years in continuous operation under the condition of appropriate maintenance. |
|
|
|
Flexibly customized
|
Ruggedized solutions
|
Complete power protection solutions |
Power solutions to perfectly meet the specific requirements of customer’s industrial applications.
|
To withstand harsh environments,extreme temperatures, humidity, dust and vibrations etc. Up to IP54 protection. |
Including switchgear, DC distribution, monitoring suite. |
INPUT |
AC voltage |
|
·Single phase |
1×230V(220,240) |
·Three phase |
3×400V(380,415) |
Input voltage tolerance |
±10% |
Input Wiring |
3 Phase 3 Wirse or 3 Phase 4 Wires |
Input frequecny |
50Hz(60Hz) |
Input frequecny tolerance |
±5% |
Input Protection |
Thermic Magnetic Overcurrent protection via MCCB |
OPTIONS |
Rectifier |
Other input voltage(1×110 to 3×690VAC) |
Harmonic filter for THDi≈12% |
Blocking diode |
Surge and Lightning protections |
Voltage ripple filter |
Bettery |
Battery circuit protection box |
Battery reversed polarity detection |
Battery low-voltage disconnection contactor (LVD) |
Battery room temperature sensor |
Battery cabinet / rack |
Battery monitoring system |
System |
Parallel configurations |
Dropping diodes/DC-DC converter |
Earth fault monitoring |
Internal cabinet lighting |
Anti-condensation heater |
Output breaker |
Front-panel analog meters/digtal meters |
DC distribution |
Temparature compensation |
AC high and AC low alarm/protection |
DC high and DC low alarm/protection |
AC fault alarm |
LED test function |
Mechanical |
Other frame colour |
Up to IP55 external |
Plate thickness |
Specified cabinet identification (tag, nameplate) |
Communication |
Modbus TCP/IP |
modbus RTU(RS485) |
DNP3.0 protocol |
Volt-free contacts |
Transducers 4-20mA |
Remote monitoring |
|
|
OUTPUT |
Nominal DC voltage |
24/48/110/125/220/240/400 |
Output voltage range |
0-1.5×nominal voltage (adjustable) |
Nominal DC current |
10-1500A |
Output current range |
0-1.1×nominal current(adjustable) |
Voltage stability |
±1% in float mode, input within tolerance |
Voltage ripple |
1% RMS(with battery connected) |
Current Limitation |
Battery current limitation can be adjusted |
Filtering |
L-C Filter |
Output Protection |
Short Circuit, NH Fuse and Overvoltage protection |
BATTERY |
Type |
Lead acid or nickel cadmium,
vented or recombination and Lithium battery |
COMMUNICATION |
Communication |
RS232, Modbus RTU |
GENERAL DATA |
Operating temperature |
0 to 50 °C |
Storage temperature |
-20 to +70 °C |
Relative humidity |
< 95 % non condensing |
Operating altitude |
1000 m max without derating |
Cooling |
Fan cooling or Natural cooling according to rating |
Efficiency |
90% according to rating |
External protection |
IP20 |
Noise
(at 1m in front of the unit) |
55 – 65 dB according to rating |
Cabinet color |
RAL 7035 |
Dimensions |
Varying according to ratings & options |
STANDARDS |
IEC60146-1-1:2009 |
Semiconductor converters –
Specification of basic requirements |
IEC62040-1:2008+AMD1:2013 |
Uninterruptible power systems (UPS)
– Part 1-2: General and safety requirements
for UPS in restricted access locations |
IEC62040-2:2006 |
Uninterruptible power systems (UPS) – Part 2:
Electromagnetic compatibility (EMC) requirements |
IEC61439-1:2011 |
Low voltage switchgear and controlgear assemblies –
Part 1: General rules |
IEC60529:1989+
AMD1:1999 |
Degrees of protection provided by enclosures (IP Code) |
IEC60076-11:2004 |
Power transformers – Part 11: Dry type transformers |
European Directives |
Low voltage directive: 2006/95/EC and 2014/35/EU
EMC directive: 2004/108/EC and 2014/30/EU
CE Mark |
|