| Brand | |
|---|---|
| Customer Application |
Airports |
| Customer Type |
Airports |
| Brand | |
|---|---|
| Customer Application |
Airports |
| Customer Type |
Airports |
EverExceed 132 cell half cut solar modules are assembled with multi-busbar PERC cells, the half-cell configuration of the modules offers the advantages of higher power output, better temperature-dependent performance, reduced shading effect on the energy generation, lower risk of hot spot, as well as enhanced tolerance for mechanical loading.
Technical Features
![]() |
![]() |
![]() |
| PERC high efficiency 182*182mm solar cells | PID resistant function |
Low resistance loss and improved shade tolerance
|
![]() |
![]() |
![]() |
| Higher performance under low light environment | Insured linear 30-year power output guarantee up to 80%,
15-year product warranty for materials and processing |
Multiwire technology for superior reliability and performance |
Product Details
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|

| Model | ESM-610MH | ESM-615MH | ESM-625MH | ESM-630MH | ESM-635MH | ESM-640MH |
| ELECTRICAL CHARACTERISTICS | ||||||
| Power output (Wp) | 610W | 615W | 625W | 630W | 635W | 640W |
| Max. power voltage (Vmp) | 41.83V | 42.01V | 42.37V | 42.54V | 42.72V | 42.90V |
| Max. power current (Imp) | 14.58A | 14.64A | 14.75A | 14.81A | 14.86A | 14.92A |
| Open circuit voltage (Voc) | 49.46V | 49.61V | 49.91V | 50.06V | 50.21V | 50.36V |
| Short circuit current (Isc) | 15.51A | 15.57A | 15.69A | 15.75A | 15.81A | 15.87A |
| Module efficiency (%) | 22.58% | 22.77% | 23.14% | 23.32% | 23.51% | 23.69% |
| Maximum system voltage (V) | 1500V | 1500V | 1500V | 1500V | 1500V | 1500V |
| Maximum series fuse rating (A) | 30A | 30A | 30A | 30A | 30A | 30A |
| Power output tolerance | ±5W | ±5W | ±5W | ±5W | ±5W | ±5W |
| FF(%) | 79.50% | 79.62% | 79.81% | 79.91% | 79.97% | 80.09% |
| TEMPERATURE CHARACTERISTICS | ||||||
| Isc (α) +0.046% / °C | ||||||
| Voc (β) -0.244% / °C | ||||||
| Pmax (γ) -0.255% / °C | ||||||
| Nominal operating cell temperature 43°C (+/- 2°C) | ||||||
| CONSTRUCTION | ||||||
| Cells | 132cells | |||||
| Cells size | 182x 105mm | |||||
| Junction box | IP68 | |||||
| Diodes | 3 by-pass diodes | |||||
| Glass | 2.0m m/2.0mm(Semi-tempered glass) | |||||
| Frame | Aluminium Alloy | |||||
| Weight | 33.5kg | |||||
| Dimension | 2382mm×1134mm×30mm | |||||
| OTHER CHARACTERISTICS | ||||||
| Operating temperature | -40°C to 85°C | |||||
| Max. load | 5400Pa (front) / 2400 Pa(back) | |||||
| Fire performance Class C (IEC) | Class C (IEC) | |||||
| Cable length | TUV/4m m²/-200mm/+300mm | |||||
| Connector | MC4 compatible | |||||