The WhisperPower GI isolation transformer is an indispensable component for safe and professional installations on board yachts and ships. An isolation transformer prevents electrolytic corrosion and also ensures a safe electrical system.
These products are very solid and reliable that will always do their job. Also, they are quiet in operation with very high efficiency. The built-in soft start ensures that the current is switched on gradually so that the shore fuse is not overloaded.
Product specifications
ARTICLE NUMBER |
60110102 |
GI 3600 Compact Galvanic Isolation – transformer |
DIMENSIONS & WEIGHT |
Weight (Kg) |
28.6 |
Dimensions (HxWxD) |
380 x290 x 208 mm |
WINDING DATA |
Rated power |
3.6 kVA |
Rated voltage |
230 V / 110 V |
Rated frequency |
50 Hz / 60 Hz |
Nominal current |
16 A / 32 A |
Inrush current |
Softstart included <4 A per unit |
Tappings |
Prim/sec. mid-point (110 VAC) |
Material winding |
Copper |
Temperature rise class |
Class F 100 K |
Insulation class |
Class H 180 C |
Insulation level |
Class AC3 |
Impedance |
Secundary less than 3.0% at 3.6 kVA |
GENERAL |
No load consumption |
21 W per unit |
Full load efficiency |
>95% |
Ambient operating temperature |
-10°C .. +45°C, derating to 80°C |
Storage temperature |
-25°C to 85°C |
Operating humidity |
95% max, non-condensing |
Audible noise |
<40.0 dB(A); <50dB(A) with forced cooling |
Local user interface |
None |
PROTECTIONS |
Overcurrent, short circuit |
Not included, external breaker(s) required according to local regulations |
Temperature protection |
Automatic switch off if transformer core > 120°C |
Overvoltage protection |
Softstart is protected for overvoltage using fuse |
Earthscreen between windings |
Compliant to ABYC, can carry full fault current |
Safety |
Standards IEC 60079, IEC 60726 |
MECHANICAL |
Protection degree |
IP21 |
Connections input/output |
6 mm2 max. |
Cable gland entry |
22 mm |
Mounting holes |
M8 |
Enclosure construction |
Aluminum sheet metal |
Surface finishing |
RAL9010 white + AE80104123621 black |