10-500kVA PowerChampion TL Series Online UPS
380/400/415VAC, 3:3
EverExceed PowerChampion TL series three phase UPS offers advanced technology that increases performance and reliability: three high speed DSPs with complete digital control fully ensure high quality of power supply, high input power factor and low input current distortion. It also offers humanization design: full front access of serviceability, user friendly interface.
Technical features
![]() |
![]() |
![]() |
|
High reliability Wide input voltage window, compatible with different utilities |
Complete Protection function Intelligent self-diagnose function, all kinds of fault protection, large capability of history record storage |
High efficiency Up to 96% system efficiency, effectively saves electricity bills & Input power factor 0.99 |
![]() |
![]() |
![]() |
|
Advanced BMS Intelligent battery management, extending battery lifetime |
Easy operation Full front maintenance, digital control with three DSP & large LCD display |
Friendly communication interface RS232, RS485, USB and dry contact (programmable) |
Applications – ISP (Internet Service Provider); IDC (Internet Data Center); Computer Room; Service Center; Precision Instruments; Intelligent Equipments
| Model | PW10S | PW15S | PW20S | PW30S | PW40S |
| PW10L | PW15L | PW20L | PW30L | PW40L | |
| Capacity | 10KVA/10KW | 15KVA/15KW | 20KVA/18KW | 30KVA/27KW | 40KVA/36KW |
| Input/output | Three phase in, Three phase out | ||||
| INPUT | |||||
| Rated voltage | 380/400/415V,3Ph+N+PE | ||||
| Voltage tolerance | 304-478Vac(line-line) | ||||
| Frequency range | 40-70Hz | ||||
| Power factor | ≥0.99 | ||||
| THDi | ≤4% | ≤3% | |||
| OUTPUT | |||||
| Rated voltage | 380/400/415V | ||||
| Voltage tolerance | ±1.5% | ||||
| Rated frequency | 50/60HZ | ||||
| Overload Capability | ≤110% 60min, ≤125% 10min, ≤150% 1min, ≥150% Shut down | ||||
| THDu | ≤1% liner load, ≤5.5% non-liner load | ||||
| Crest factor | 3:1 | ||||
| Power factor | 1 | 0.9 | |||
| BATTERIES | |||||
| Type | Lead-acid maintenance-free batteries | ||||
| Voltage | ±192VDC(±216,±240 Setable) | ||||
| Battery charger | 10A MAX | ||||
| COMMUNICATION | |||||
| Interfaces | Standard: RS232, RS485, Dual input kit; | ||||
| Ethernet adapter | SNMP/Dry Contact /USB/Parallel Kits (Optional) | ||||
| Local communication software | Local View | ||||
| EFFICIENCY | |||||
| Online mode | ≥95% | ||||
| ENVIRONMENT | |||||
| Ambient service temperature | 0 °C to +40 °C (15 °C to 25 °C for maximum battery lifetime) | ||||
| Relative humidity | < 95 % non-condensing | ||||
| Maximum altitude | 1000 m without de-rating | ||||
| UPS CABINET | |||||
| Dimensions W×D×H(mm) | 250*840*715 | 250*840*715 | 350*738*1335 | 350*738*1335 | 500*840*1400 |
| 250*660*530 | 250*660*530 | 250*680*770 | 250*680*770 | 250*836*770 | |
| Weight(Kg) | 51.5 | 51.5 | 89 | 89 | 140 |
| 31 | 31 | 50 | 52 | 61 | |
| Degree of protection | IP20 | ||||
| STANDARDS | |||||
| Safety | EN 62040-1 | ||||
| EMC | EN 62040-2 | ||||
| Product certification | CE | ||||
| Model | PW60L | PW80L | PW90L | PW100L | PW120L | PW150L | PW200L | PW250L | PW300L | PW400L | PW500L |
| Sn | 60KVA | 80KVA | 90KVA | 100KVA | 120KVA | 150KVA | 200KVA | 250KVA | 300KVA | 400KVA | 500KVA |
| Pn | 60KW | 80KW | 90KW | 100KW | 120KW | 150KW | 200KW | 250KW | 300KW | 400KW | 500KW |
| Input/output | Three phase in, Three phase out | ||||||||||
| INPUT | |||||||||||
| Rated voltage | 380/400/415V | ||||||||||
| Voltage tolerance | 304-478V | ||||||||||
| Rated frequency | 40-70HZ | ||||||||||
| Power factor | ≥0.99 | ||||||||||
| THDi | ≤3%(100% non-liner load) | ||||||||||
| OUTPUT | |||||||||||
| Rated voltage | 380/400/415V | ||||||||||
| Voltage tolerance | ±1.5% | ||||||||||
| Rated frequency | 50/60HZ | ||||||||||
| Overload Capability | ≤110% 10min, ≤125% 1min, ≤150% 5S, ≥150% 200ms | ||||||||||
| THDu | ≤1% liner load, ≤5.5% non-liner load | ||||||||||
| Crest factor | 3:1 | ||||||||||
| Connections | Terminal | ||||||||||
| BATTERIES | |||||||||||
| Type | Lead-acid maintenance-free batteries | ||||||||||
| Voltage | ±240VDC(±192, ±216, ±240, ±264 Setable) | ||||||||||
| Battery charger | 20%*System Power | ||||||||||
| COMMUNICATION | |||||||||||
| Interfaces | RS232, RS485, USB, Dry contact(programmable) | ||||||||||
| Local communication software | Local View | ||||||||||
| EFFICIENCY | |||||||||||
| Online mode | 96% | ||||||||||
| ENVIRONMENT | |||||||||||
| Ambient service temperature | 0 °C to +40 °C (15 °C to 25 °C for maximum battery lifetime) | ||||||||||
| Relative humidity | < 95 % non-condensing | ||||||||||
| Maximum altitude | 1000 m without de-rating | ||||||||||
| UPS CABINET | |||||||||||
| Dimensions W×D×H(mm) | 600*980*950 | 600*980*1150 | 600*980*1400 | 600*980*1150 | 600*980*1600 | 650*960*1600 | 650*960*2000 | 1300*1100*2000 | |||
| Weight(Kg) | 170 | 210 | 231 | 210 | 266 | 305 | 350 | 445 | 490 | 810 | 900 |
| Degree of protection | IP20 | ||||||||||
| STANDARDS | |||||||||||
| Safety | EN 62040-1 | ||||||||||
| EMC | EN 62040-2 | ||||||||||
| Product certification | CE | ||||||||||