DS-UPS01K24-R/TJS/X

SKU: DS-UPS01K24-R/TJS/X Category: Tag:

DS-UPS01K24-R/TJS/X

Availability will be confirmed on request.
Check Availability

Product Specifications

  • Double conversion on-line design with input power factor correction (PFC) technology, achieving an input power factor of up to 0.99.
  • Digital control system for enhanced stability and reliability.
  • ECO operation mode for improved energy efficiency and reduced user costs.
  • Three-stage charging: constant current charging, constant voltage charging, and floating charging stages are intelligently managed.
  • Wide voltage input and frequency range for stable operation with different electrical scenario, and suit with various fuel generators.
  • Comprehensive protections including output overload, output short-circuit, over-temperature, battery under-voltage warning, battery over-charging protection, and power-on self-diagnostic function;

Available models:

  • DS-UPS01K24-R/TJS/X
  • DS-UPS01K24-R/TJS/X

Power

  • UPS Capacity : 1000 VA / 900 W

Input

  • Nominal Voltage : 100/110/115/120/125Vac
  • Phase : Single Phase
  • Input Voltage Range : 55~150Vac (90~150Vac @ 100% load)
  • Input Frequency : Frequency range 40~70Hz (50/60Hz Auto-Sensing)
  • Power Factor : ≥0.99

Output

  • Output Voltage : 100/110/115/120/125Vac
  • Crest Factor : 3:1
  • Power Factor : 0.9
  • Output Sockets : IEC panell/US panel Optional
  • Output Frequency : Line mode: 46~54Hz/56~64Hz, sychronize with input; Bat. Mode: 50/60±0.1Hz
  • Harmonic Distortion (THDv) : 2% Linear load; 5% Non-linear load
  • Transfer Time : AC mode to Bat.mode: 0ms; Inverter to Bypass: 4ms (Typical)
  • Output Waveform : Pure Sinewave

Battery

  • Battery Type : Valve Regulated Lead Acid (VRLA)
  • Typical Recharging Time : 4 hours (To 90% of full capacity)
  • Capacity (Standard Unit) : 12V/9Ah
  • Battery Number : 2
  • DC System Voltage (VDC) : 24V
  • Charging Current (Max.) : 2A
  • Expandable Runtime : Yes

Indicator

  • Alarm : Battery mode/Battery low voltage/Overload/Fault
  • LCD Display : Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time

Efficiency

  • AC Mode : 91%
  • Battery Mode : 95%

Environment

  • Operating Temperature : 0℃~40℃
  • Storage Temperature : -25℃~55℃
  • Humidity Range : 0~95% (Non – condensing)
  • Altitude : 0~3000m (1000~3000m derating required)
  • Noise Level : ≤50dB

Physical

  • Dimension W X D X H (Mm) : 440 x 325 x 86.5
  • Net Weight (Kg) : 12.1

Standards

  • Safety : UL1778 5th Edition CSA C22.2 NO.107.3-14
  • EMC : ICES-003 Issue 7:2020