Whisperpower isolation transformers offer optimal safety by eliminating shock hazards to life beings on board and in the water adjacent to a boat, by preventing AC current flow from the shore to metal objects on a boat, thereby stopping nuisance tripping of RCD (residual current device) or GFCI (ground fault circuit interrupt) systems when on shore power.
Our isolation transformers also reduce possible galvanic corrosion of hulls, propellers, or other metal parts under a ship, eliminating the need for installing galvanic isolators, sacrificial anodes and polarity alarms. By preventing DC currents traveling between a shore ground connection and metal parts of a ship, no current flow path between two dissimilar metals (electrically in contact and simultaneously exposed to an electrically conductive liquid) can occur, and corrosion is thus prevented.
It is important, therefore, that the Ground conductor from the Shore connection is NOT CONNECTED to the Power Inlet housing nor the Isolation Transformer enclosure PE (except temporarily when in dry-dock). On the floating AC output of the Isotransformer, it is possible to jumper a Neutral-Ground bond for allowing GCFI/RCD breakers onboard.
Warning: Never disconnect the shore Ground (PE) conductor unless you use an Isotransformer. Because GCFI/ RCD will not trip, nor a fuse will blow in the case of a short circuit current to metal parts on a vehicle, always use an Isotransformer with Neutral-Ground bond on the secondary.
ARTICLE NUMBER | |
---|---|
61224200 | Isotransformer 2000 |
WINDING DATA | |
---|---|
Rated power | 2.0 kVA |
Rated input voltage | 240 V or 120 V |
Rated output voltage | 240 V or 120 V |
Rated frequency | 50 Hz / 60 Hz |
Nominal current | 8 A / 16 A |
Circuit Breaker | 12 A / (effectively 24 A for 120 V) |
Inrush current | Soft start included |
Transformer type | Toroidal (low noise, low weight) |
GENERAL | |
---|---|
No load consumption | less than 10 W |
Ambient operating temperature | -10°C .. +45°C, derating above 45°C |
Storage temperature | -25°C to 85°C |
Operating humidity | 95% max, non-condensing |
Audible noise | <40.0 dB(A); <54dB(A) with forced cooling |
Local user interface | None |
Weight | <12.5 kg |
Dimensions (HxWxD) | 432 x 213 x 128 mm |
PROTECTIONS | |
---|---|
Overcurrent, short circuit | Circuit Breaker included |
Temperature protection | Automatic switch off if transformer core > 120°C |
Overvoltage protection | Soft start is protected for overvoltage using fuse |
Safety Standards | IEC 60079, IEC 60726 |
MECHANICAL | |
---|---|
Protection degree | IP21 |
Connections input/output | 6 mm2 max. |
Cable gland entry | 16 mm |
Mounting holes | M6 |
Enclosure construction | Aluminum sheet metal |
Surface finishing | RAL9010 white + AE80104123621 black |