The DC Modular Remote Battery Switch 48 V / 350 A is a smart high current magnetic latching contactor, that can handle continuous DC currents of up to 350 Amps. The Remote Battery Switch 48 V / 350 A can easily be installed in an engine room or battery compartment while being controlled from a more convenient location by a small panel mounted switch. But the Switch can for instance also be controlled by a battery monitor or Lithium battery, as a discharge/overcharge protection.
ARTICLE NUMBER | |
---|---|
50214718 | Remote Battery Switch 48 V / 350 A |
PARAMETER | |
---|---|
Rated voltage | 60 VDC |
Nominal current @ 25 C | 500 A (see precaution #2) |
Cranking current (1min.) | 1000 A |
Nominal make / break current | 350 A (35 – 60 VDC) |
Peak make / break current | 1200 A (35 – 60 VDC) (Install proper pre-charge circuit to keep peak make current significantly below this value) |
CONTROL CIRCUIT (ELECTRICAL) | |
---|---|
Coil / supply voltage (+ VDC) | 34 – 68 VDC |
Coil / supply current (idle state (1) | < 100 qA |
Coil / supply current (state change (1) | < 1.5 A |
(1) = | Due to the magnetic latch construction, the DCM-RBS draws virtually no current in the ON or OFF state. A current draw only exists shortly (500 ms max.) when changing the state of the contact. |
GENERAL | |
---|---|
Remote control | By control wires |
Local control (2) | Top side buttons (On/Standby, Close contact, Open contact) |
Length x width x height | 150 x 50 x 94 mm (5.9″ x 2″ x 3.7″ inch) |
Weight | 0.8 kg (1.8 lb.) |
Indicators | Top side LEDs for Contact open, Contact closed, Error and Setup |
Mechanical life | 100000 cycles |
Electrical life | 10000 cycles |
Operating temperature range | – 20 .. + 60 °C |
Connection stud size / DCM grid size | M10 / 1 x 3 |
Protection class | IP65 |
Standards | CE certified (EMC Directive 2014/30/EU, Low voltage Directive 2014/35/EU, RoHS Directive 2011/65/EU and Ignition protection standard ISO 8846) |
(2) = | Using the top side buttons, one can manually override the switch state as commanded through the control wires. A dedicated ‘On / Stand’ button also allows the user to put the DCM-RBS in a standby mode with open contact. In this mode any command from the control wires and/or manual override buttons are ignored. |