| Brand |
|---|

| Brand |
|---|
Meet the automatic battery charger: Supreme 12 VDC – 100 A with multiple outputs. Engineered for integration in automotive and nautical vessels, such as cars and yachts. Capable of charging three independent batteries. This charger offers user-friendly configuration for AGM, GEL, Lead-acid and Lithium battery types. Offering international adaptability, Supreme chargers can manage input voltages from 90 to 265 VAC (50/60 Hz).

| ARTICLE NUMBER | |
|---|---|
| 61112310 | Supreme 12 VDC – 100 A |
| DIMENSIONS & WEIGHT | |
|---|---|
| Weight | 6.4 Kg / 14.1 lb. |
| Length x width x height, mm (in.) | 425 x 236 x 103 (16.7 x 9.3 x 4.1) |
| TECHNICAL SPECIFICATIONS | |
|---|---|
| Output Current (Maximum) | 100 A |
| Output Voltage Charge | 14.2 – 15.5 V |
| Output Voltage Float | 13.4 – 13.8 V |
| Output Voltage Equalize | 16.0 V |
| Charging Control | 3-step (Bulk/Absorption/Float) |
| DC Output Bank | 3 |
| Selectable Battery Type | GEL, AGM, Lithium and open lead acid |
| Parasitic Current | < 2 mA |
| CHARGER INPUT | |
|---|---|
| AC Input Voltage (Nominal) | 120, 230, 240 VAC |
| AC Input Operating Range | 90 – 265 VAC |
| AC Input Frequency Range | 47 – 63 Hz |
| Power Consumption (Full Load) | 1800 W |
| Power Factor Correction | Yes |
| Charger Efficiency | > 84% |
| PROTECTION AND FEATURES | |
|---|---|
| Reverse Battery | Yes, unit shutdown |
| Over Charge | Yes, unit shutdown |
| Over Heating | Yes, unit de-rated and shutdown |
| Output Short Circuit | Yes, unit shutdown |
| Cooling | Mechanical |
| Temperature Setting | Hot, Normal, Cold (no sensor connected) |
| Battery Temperature Sensor Port | RJ12 (battery temp. sensor use) |
| Digital Display Port | RJ12 (optional remote display panel) |
| DISPLAY | |
|---|---|
| LCD Display (with back lighting) | Charging status, Battery Voltage |
| Warning and Fault Code | A01-02, E01-09 |
| AC INPUT AND DC OUTPUT CONNECTION | |
|---|---|
| AC Input Connection | Hardwire or AC Cord |
| DC Output Connection | Heavy Duty Studs (3 banks) |
| DC Output Ground | Single Heavy Duty Common Ground Stud |
| ENVIRONMENTAL AND OPERATING TEMPERATURE | |
|---|---|
| Storage Range | -40° to 70°C |
| Operating Range | -20° to 60°C |
| Humidity | 5-95%, non-condensing |
| Ingress Protection | IP32 (24/20 IP65) |