Wired Input Expander(Cascade)

SKU: DS-PM1-I8O2-H Category: Tags: , , ,
Additional information
Brand
Customer ApplicationAirports
Customer TypeAirports, Army, Commercial, Government Entities, Healthcare, Industrial, Jail / Prison, Law Enforcement, Medical, Navy / Coastal Protection, Oil & Gas, Other Businesses, Private Entities, Security Firms, Space & Research
Description
  • 8 on-board wired zones
  • Support 3EOL connection(Alarm: 1KΩ; Tamper: 1KΩ; Fault: 2.2KΩ)
  • Support zone alarm, tamper, masking, fault, short detection
  • 1 power output for wired detectors
  • 2 Speed-X bus, supporting wired input expander cascade mode

Available models:

  • DS-PM1-I8O2-H

Hardware features

  • Alarm input : 8
  • IO Output : 2 (connect to relay module)
  • Bus : 2×Speed-X bus, 1 input for control panel connection and 1 output for expander cascading
  • Tamper-Proof : Support (front and rear)

Electrical characteristics

  • Power supply : 11 to 24 VDC
  • Typical voltage : 12 VDC
  • Power consumption : Maximum current: 119 mA@12 VDC; Quiescent current: 45 mA@12 VDC
  • Output Voltage : 9 to 12 VDC
  • Output Current : Maximum 500 mA

Display

  • LED Indicator : LED indicators: 1 for power, 1 for fault

General

  • Operation temperature : -10°C to 40°C
  • Operation humidity : 10% to 90%
  • Shell material : Plastic
  • Dimension(WxHxD) : 110 mm × 155 mm × 32 mm
  • Weight : 252.5 g