1kVA/ 2kVA/ 3kVA rack mounted UPS, 208/220/230/240 VAC, 1:1
PowerLead3 RM series power supply adopts online double conversion design and digital control technology and it features high input and output power factor, self-adaptive output frequency according to input frequency,intelligent battery management and excellent network management.
Key Features:
IDC( Inte rnet Dater Center), network, servers and workstations, control system, communication system, office, PC etc.
MODEL | PL3 RM1KS | PL3 RM1KL | PL3 RM2KS | PL3 RM2KL | PL3 RM3KS | PL3 RM3KL |
Capacity | 1kVA/1kW | 1kVA/1kW | 2kVA/2kW | 2kVA/2kW | 3kVA/3kW | 3kVA/3kW |
Phase | 1 Phase in/1 Phase out | |||||
INPUT | ||||||
Nominal Voltage | 208/220/230/240VAC (L-N Voltage), L+N+PE | |||||
Input Voltage Range | 110~300VAC | |||||
Input Frequency Range | 50/60±6Hz | |||||
Input Power Factor | >0.99 | |||||
Input Current Distortion (THDi) | ≤4%(linear load);≤5%(non-;linear load) | |||||
Bypass Voltage Range | -40%~20% of nominal voltage, adjustable | |||||
OUTPUT | ||||||
Nominal Votage | 208/220/230/240VAC , L+N+PE | |||||
Voltage Regulation | ± 1 % | |||||
Nominal Frequency | 50/60Hz, adjustable | |||||
Output Frequency | Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz | |||||
Output Power Factor | 1 | |||||
Output Voltage Distortion (THDu) | ≤2%@linear load; ≤5%@non-linear load | |||||
Transfer Time | Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time) | |||||
Crest Ratio | 3:1 | |||||
Overload Capacity
(Line Mode)
|
30 min @ 102%~110% load;10 min @ 110%~130% load;30s @130%~150% load;200 ms @ >150% load | |||||
Overload Capacity
(Battery Mode)
|
1 min @ 102%~110% load;10s @ 110%~130% load;3s @130%~150% load;200 ms @ >150% load | |||||
Overload Capacity
(Bypass Mode)
|
Depending the input breaker (10A) | Depending the input breaker (20A) | ||||
Output Short Circuit Protection | Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker | |||||
BATTERY | ||||||
Battery Type | Sealed Lead Acid Maintanance Free (VRLA) | |||||
Nominal Voltage | 24VDC | 36VDC | 48VDC | 72VDC | 72VDC | 96VDC |
Charging Voltage | Floating | |||||
Battery Number&Capacity | 2 pcs, 12V/9Ah | External | 4 pcs, 12V/9Ah | External | 6pcs, 12V/9Ah | External |
Charging Current | 1A-4A,adjustable, default 1A | 1~12A, adjustable | 1A-4A,adjustable, default 1A | 1~12A, adjustable | 1A-4A,adjustable, default 1A | 1~12A, adjustable |
Charging Mode | Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable) | |||||
Battery Protection | Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection, Over Current Protection;Battery Deep Discharge Protection | |||||
EFFICIENCY | ||||||
Line Mode | 94.5% (Max) | 95.5% (Max) | 95.5% (Max) | |||
Battery Mode | 88.5% (Max) | 89.5% (Max) | 91.5% (Max) | |||
ECO Mode | 98% | |||||
INDICATORS | ||||||
LCD Panel | UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code | |||||
Audible Alarm | Utility Failure, Battery Voltage Low, Overload, System Fault | |||||
MANAGEMENT | ||||||
Interface | RS232 ,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional) | |||||
ENVIRONMENT | ||||||
Operating Temperature | 0~40℃ | |||||
Operating Humidity | 0~95% RH, non-condensing | |||||
Storage Temperature | -15~60℃ (Battery: 0-40℃) | |||||
Altitude | <1000m, derating 1% per 100m from 1000~ 2000m | |||||
Noise (1Meter Away) | <50dB@ 1 meter away | |||||
PHYSICAL | ||||||
Dimension(W*D*H, unit:mm) | 440*379*86 | 440*379*86 | 440*568*86 | 440*450*86 | 445*560*86 | 440*450*86 |
Net Weight (kg) | 8.6 | 4 | 18 | 8 | 24 | 10 |
Color | Black ( RAL9004) | |||||
STANDARDS | ||||||
Safety | IEC 62040-1:2017 | |||||
EMC | IEC 62040-2:2018 | |||||
Performance | IEC 62040-3:2011 | |||||
Battery | IEC 60896-22:2004 |